Description
F E A T U R E S
- CO2 Monitoring & Control
- CO2 Safety/Evacuation
- Dual-Band Infrared CO2 Sensor: 0-10,000 PPM
- Precision Temperature Sensor: 30-100°F ± 0.2°F
- RH Sensor: 0-100% RH ± 3%
- Optional PAR Sensor for Realtime Readings
- and Light Control
- Control Outputs
- Web Interface for Remote Access, Data Logging, & Programming
- Interior/Exterior Room LED Visual Alarm Option
- Optional Oxygen Sensor
SPECIFICATIONS
UNIT SPECS
Operating Temperature 32°F – 104°F
Integrated Sensors Carbon Dioxide, Temperature, Relative Humidity
Power Source 120VAC
Power Consumption Dependant on Connected Devices
Communications GC Web Dashboard, Local Web Dashboard
CARBON DIOXIDE SENSOR
Detection Range 360 – 10,000ppm CO2
Detection Technology Non-Dispersive Infrared (NDIR); Single Light Source, Dual Wavelength
Accuracy ±50ppm+3% of reading in the range of 360 – 5,000ppm CO2
Pressure Dependancy Approx 1% of reading/kPa
Response Time 90 seconds (Diffusion)
TEMPERATURE SENSOR
Accuracy ±0.9°F (-13°F – 185°F)
HUMIDITY SENSOR
Operating Humidity Range 0 – 100% RH (Maximal Dew Point = +185°F)
Accuracy < ±3% RH (15 – 85% RH at +73.4°F)
< ±5% RH (0% – 15% RH and> 85% RH at +73.4°F)
Response Time < 5s (50 – 0% RH) at +185°F
OPTIONAL LIGHT SENSOR
Detection Technology Full Spectrum PAR
Detection Range* 0-4000 µmol m-2 s-1
AUDIBLE/VISUAL STROBE ALARM (OPTIONAL)
Voltage 10-24VDC
Number of LEDs 54
Lens Color Amber
Current Draw 90 – 350mA (Setting Dependent)
IP Rating IP55
GC Cinque Room Controller: a Carbon Dioxide, Relative Humidity, Temperature, and Room Controller in One Box!